Skip to content
Goshen Exchange

WaterLesson 3 of 7

Wells and pumps

Breakout About 8 min readNew to you

What you’ll learn

  • How well types differ and where a well can safely go
  • How to protect the wellhead and what permits and water rights may apply
  • How pumps, pressure switches and pressure tanks work, and how to size them
  • What to do after a flood, and how shock chlorination is done
  • The electrical, confined-space and generator rules that keep you alive

The short version

  1. Test a private well every year for total coliform, nitrate, TDS and pH at a state-certified lab, and again after floods, repairs or a change in taste or smell.

  2. Keep a well 50 ft or more from septic tanks and livestock yards and 100 ft or more from drain fields in most states. Check your state's table.

  3. Don't turn on a flooded well's pump until a qualified person checks the wiring, and never enter a well pit.

  4. Know your water right. In Colorado, Utah and other western states you can't take ditch or creek water, or use some wells outdoors, without one.

Well types and siting

  • Dug or bored wells are about 10–30 ft deep and not cased continuously; driven wells are about 30–50 ft; drilled wells are continuously cased and can run thousands of feet. Shallow wells are more likely to be contaminated by surface water, septic systems or spills, and they go dry in drought.

  • Put the well at the highest practical spot, not down slope from contamination, not where runoff ponds, and not in a basement, pit or building other than a well house.

Diagram coming soonSetback map
Figure 2. Setback distances differ by state. Check yours.
Sources: U.S. Environmental Protection Agency, Minnesota Department of Health, Well Management Section and 10 more

Wellhead protection

  1. Casing height: 12 in above ground in Wisconsin, North Carolina, New York and Texas, 18 in in Utah; Penn State recommends 8 in. Flood-prone sites need more (2 ft above the flood level in Wisconsin and Georgia).

  2. Grade the ground to slope away; use a vermin-proof, weatherproof cap with a screened vent.

  3. Grout and seal: Minnesota requires grout pumped in from the bottom up, never poured from the surface; New York casing runs from 1 ft above grade to 19 ft below with grout.

  4. Abandoned wells must be properly filled and sealed; Texas makes the landowner liable; Minnesota lets only licensed contractors seal them.

Diagram coming soonWell anatomy
Figure 1. Parts of a drilled well, from cap to pressure tank.
Sources: Wisconsin Legislative Reference Bureau, North Carolina Office of Administrative Hearings and 9 more

Permits and rights (checked 2026-10-04)

  • Licensed drillers are required in many states. Minnesota, Wisconsin and Utah let owners build a well or install a pump on their own land under conditions; Georgia requires a licensed contractor and notice to the county.

  • Colorado: exempt wells are generally limited to 15 gpm and, on small parcels, to household use inside one dwelling; permit review can take up to 49 days.

  • Utah: every well needs State Engineer approval.

  • Texas: groundwater districts exempt domestic and livestock wells on 10+ acres under 25,000 gal a day. Washington: permit exemption for 5,000 gal a day domestic and a half-acre of lawn and garden.

Sources: Minnesota Department of Health, Well Management Section, Wisconsin Legislative Reference Bureau and 8 more

Pumps and pressure tanks

PumpUseNotes
SubmersibleDrilled wells, casing 4 in or largerIn the well, below frost; pull it to repair
Shallow-well jetWater less than 25 ft downAbove ground; needs frost protection and priming
Deep-well jetWater 25–250 ft down (Minnesota: usually under 200)Lower pressure and yield than submersibles
  • Pressure switch: typically starts the pump at 30 or 40 psi and stops it about 20 psi higher.

  • Tank pre-charge is 2 psi below the pump-on pressure (28 psi for a 30-psi start), measured with the tank drained and power off.

  • Tank size: about 4 × pump gpm (a 9-gpm pump needs about 36 gal). Only about 20% of a tank is usable water; a bigger tank alone won't fix a low-yield well.

  • Demand: 80–100 gal per person a day; size for a day's use in a 2-hour peak. A minimum of 6 gpm is suggested for most homes. A 1-gpm well gives 1,440 gal a day but only 120 gal in a 2-hour peak. A 6-in well stores about 1.5 gal per foot of water.

  • Livestock per day: milking cow 35 gal, beef cow or horse 12, sheep or goat 2, swine 1.5, chickens 9 per 100.

Diagram coming soonPressure-tank cutaway
Figure 3. Pre-charge for a 30-psi pump start.
Sources: Nebraska Extension, Minnesota Department of Health, Well Management Section and 1 more

Safety

Diagram coming soonConfined-space warning
Figure 6. Never enter a well pit.
Sources: Minnesota Department of Health, Virginia Cooperative Extension and 4 more

Flooded wells

Diagram coming soonFlooded-well steps
Figure 4. After a flood: pump off, wiring checked, then bleach.
Sources: U.S. EPA Office of Water, U.S. Environmental Protection Agency and 2 more

Shock chlorination

Use it after construction, any repair, a positive coliform test or flooding, and not as a cure for recurring bacteria. Find and fix the source (a failing septic system, loose cap, cracked casing). Penn State found it kept contaminated wells clean for a year in only about 15% of cases.

Diagram coming soonShock chlorination comparison
Figure 5. Agencies differ. Follow one procedure.
Sources: Penn State Extension, Virginia Cooperative Extension and 7 more

Troubleshooting

ProblemLikely causeWhat to do
No waterPower, breaker, or pump set too high in a droughtCheck the breaker, then call a pro
Pump runs constantlyStuck check valve or a line breakLook for a soggy spot; call a pro
Pump cycles a few secondsToo little air in the pressure tankCheck the pre-charge (power off)
Sand in the waterPoorly built well or a hole in the screenContractor
Rotten-egg smell, hot tap onlyWater-heater anodeReplace or remove the anode
Rotten-egg smell, both tapsSulfur bacteria or hydrogen sulfideTest coliform and nitrate; treat
Sources: Nebraska Extension, Minnesota Department of Health, Well Management Section

Costs (dated)

  • Drilling anchors are old livestock-well scenarios, not current prices: NRCS FY2014–15 about $37 a foot for 6-in drilled wells of about 100 ft (Iowa, Missouri), $17–$29 a foot for 300–400 ft wells, $147–$195 a foot for dug or large-diameter wells.

Sources: USDA Natural Resources Conservation Service, Iowa, USDA Natural Resources Conservation Service, Arkansas and 2 more

Common mistakes

  1. Never testing a private well, or testing only once.

  2. Siting a well or a manure pile too close to each other or to a septic field.

  3. Turning on a flooded well's pump before the wiring is checked.

  4. Using scented or pool bleach for shock chlorination, or flushing the chlorinated water into the septic system or garden.

Sources: CDC, Washington State Legislature and 3 more

Resources

By zone

Frost depth and local rules shape how a well is built. Here is what shifts by zone and region.

3–4
Pitless adapters and pits matter for wells. Test for arsenic and radon in rock wells.

Where this comes from

Every fact in this lesson was checked against 46 published sources, all from extension services, the USDA and research journals. Each section lists its own at the bottom.

See all 46 sources
Colorado Division of Water Resources, Department of Natural Resources
North Carolina Office of Administrative Hearings
Pennsylvania Department of Environmental Protection
Pennsylvania Department of Health
Texas A&M AgriLife Extension Service, Texas Well Owner Network
Utah Division of Water Rights
Washington State Department of Ecology

Summary

The whole lesson on one page. Print it or come back to it.

Key information

  • Test a private well every year for total coliform, nitrate, TDS and pH at a state-certified lab, and again after floods, repairs or a change in taste or smell.
  • Keep a well 50 ft or more from septic tanks and livestock yards and 100 ft or more from drain fields in most states. Check your state's table.
  • Don't turn on a flooded well's pump until a qualified person checks the wiring, and never enter a well pit.
  • Shock chlorination is not a cure for recurring bacteria. Find and fix the source, and follow one agency's whole procedure.
  • Pressure-tank pre-charge is 2 psi below the pump-on pressure (28 psi for a 30-psi start), measured with the tank drained and power off.
  • Know your water right. In Colorado, Utah and other western states you can't use some wells outdoors without one.

Step by step

  1. 1.Site the well at the highest practical spot, not down slope from contamination.
  2. 2.Check your state's rules on driller licenses, permits, setbacks and water rights.
  3. 3.Protect the wellhead: casing above ground, ground sloped away, and a vermin-proof, weatherproof cap with a screened vent.
  4. 4.Match the pump type to how far down the water is, then set the pressure switch and tank pre-charge.
  5. 5.Test the water every year, and after a flood or repair.

Made it to the end? I’ll keep track for you on this device.